Eton 10KW Infinisolar

SPECIFICATIONS

 

  • Self-consumption and feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable battery charging current suits different types of batteries
  • Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
  • Built-in Timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real time status display and control
  • Custom-made firmware by ODM contract
  • Parallel operation up to 6 units
warranty 2
Infini Solar
MODELETON 10 KW
Phase3-phase in / 3-phase out
Maximum PV Input Power14850 W
Rated Output Power10000 W
Maximum Charging Power9600 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage320 VDC / 350 VDC
MPP Voltage Range400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current2 /2 x 18.6 A
GRID OUTPUT (AC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range184 – 265 VAC* per phase
Nominal Output Current14.5 A per phase
Power Factor> 0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)96 %
European Efficiency @ Vnominal95 %
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120 – 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range170 – 280 VAC per phase
Maximum AC Input Current40 A
PV INPUT (DC)
Maximum DC Voltage900 VDC
MPP Voltage Range400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current2 / 2 x 18.6 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output WaveformPure sine wave
Efficiency (DC/AC)91 %
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage270 VDC / 900 VDC
Start-up Voltage / Initial Feeding v320 VDC / 350 VDC
MPP Voltage Range400 VDC ~ 800 VDC
Number of MPP Trackers / Maximum Input Current2 / 2 x 18.6 A
GRID OUTPUT (AC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range184 – 265 VAC* per phase
Nominal Output Current14.5 A per phase
AC INPUT
AC Start-up Voltage / Auto Restart Voltage120 – 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range170 – 280 VAC per phase
Maximum AC Input Current40 A
BATTERY MODE OUTPUT (DC)
Nominal Output Voltage230 VAC (P-N) / 400 VAC (P-P)
Maximum Charging Current91 %
BATTERY & CHARGER
Nominal DC Voltage48 VDC
Maximum Charging CurrentDefault 60 A, 10 A -200 A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm)167.2 x 500 x 622
Net Weight (kgs)40
INTERFACE
Communication PortsRS-232 / USB
Intelligent SlotOptional SNMP, Modbus and AS-400 cards available
ENVIRONMENT
Humidity0 ~ 90% RH (Non-condensing)
Operating Temperature-10°C to 50°C
Altitude0 ~ 1000 m**