Eton 10KW Infinisolar
SPECIFICATIONS
- Self-consumption and feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
- Built-in Timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real time status display and control
- Custom-made firmware by ODM contract
- Parallel operation up to 6 units


MODEL | ETON 10 KW |
---|---|
Phase | 3-phase in / 3-phase out |
Maximum PV Input Power | 14850 W |
Rated Output Power | 10000 W |
Maximum Charging Power | 9600 W |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC |
MPP Voltage Range | 400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current | 2 /2 x 18.6 A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 – 265 VAC* per phase |
Nominal Output Current | 14.5 A per phase |
Power Factor | > 0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 96 % |
European Efficiency @ Vnominal | 95 % |
OFF-GRID OPERATION | |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase |
Acceptable Input Voltage Range | 170 – 280 VAC per phase |
Maximum AC Input Current | 40 A |
PV INPUT (DC) | |
Maximum DC Voltage | 900 VDC |
MPP Voltage Range | 400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 18.6 A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform | Pure sine wave |
Efficiency (DC/AC) | 91 % |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage / Maximum DC Voltage | 270 VDC / 900 VDC |
Start-up Voltage / Initial Feeding v | 320 VDC / 350 VDC |
MPP Voltage Range | 400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current | 2 / 2 x 18.6 A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 – 265 VAC* per phase |
Nominal Output Current | 14.5 A per phase |
AC INPUT | |
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase |
Acceptable Input Voltage Range | 170 – 280 VAC per phase |
Maximum AC Input Current | 40 A |
BATTERY MODE OUTPUT (DC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Maximum Charging Current | 91 % |
BATTERY & CHARGER | |
Nominal DC Voltage | 48 VDC |
Maximum Charging Current | Default 60 A, 10 A -200 A (Adjustable) |
GENERAL | |
PHYSICAL | |
Dimension, D x W x H (mm) | 167.2 x 500 x 622 |
Net Weight (kgs) | 40 |
INTERFACE | |
Communication Ports | RS-232 / USB |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0 ~ 90% RH (Non-condensing) |
Operating Temperature | -10°C to 50°C |
Altitude | 0 ~ 1000 m** |