Thunder 3KW-5KW VM II

SPECIFICATIONS

 

  • Output power factor 1
  • Pure sine wave solar inverter
  • Selectable high power charging current
  • Wide DC input range
  • Selectable input voltage range for home appliance and personal computers
  • Configurable AC/Solar input priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload and short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function
warranty 2
new
MODELTHUNDER 3KWTHUNDER 5KW
Rated Power3000 VA / 3000 W5000 VA / 5000 W

INPUT

Voltage230 VAC230 VAC
Selectable Voltage Range170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances)170-280 VAC (For Personal Computers); 90-280 VAC (For Home Appliances)
Frequency Range50 Hz / 60 Hz (Auto sensing)50 Hz / 60 Hz (Auto sensing)

OUTPUT

AC Voltage Regulation (Batt. Mode)230 VAC A± 5 %230 VAC A± 5 %
Surge Power6000 VA6000 VA
Efficiency (Peak)90 % to 93 %90 % to 93 %
Transform Time10 ms (For Personal Computers); 20 ms (For Home Appliances)10 ms (For Personal Computers); 20 ms (For Home Appliances)
WaveformPure sine wavePure sine wave

BATTERY

Battery Voltage24 VDC48 VDC
Floating Charge Voltage27 VDC54 VDC
Overcharge Protection33 VDC63 VDC

SOLAR CHARGER & AC CHARGER

Maximum PV Array Open Circuit Voltage500 VDC500 VDC
Maximum PV Array Power4000 W4000 W
MPP Range @ Operating Voltage120 ~ 450 VDC120 ~ 450 VDC
Maximum Solar Charge Current80 A80 A
Maximum AC Charge Current60 A60 A
Maximum Charge Current80 A80 A

PHYSICAL

Dimension, D x W x H (mm)100 x 300 x 440100 x 300 x 440
Net Weight (kgs)910
Communication InterfaceUSB / RS232USB / RS232

ENVIRONMENT

Humidity5% to 95% Relative Humidity (Non-condensing)5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 50°C-10°C to 50°C
Storage Temperature-15°C to 60°C-15°C to 60°C
Product specifications are subject to change without further notice